New network design
Customers by distance from the PON interface: distance m, current, future per line (paste CSV or upload). Sample data below, replace with your own.
Parameter guide
Inputs
- PON technology / receiver limits
- Sets the standard receiver limits. GPON Class B+ and C+ are optical classes (power budget about 28 dB and 32 dB). Pick Custom for XGS-PON or other equipment and type your datasheet values.
- OLT launch power (dBm)
- Optical power the OLT PON port transmits into the fibre. Everything downstream is this number minus losses. Use your OLT SFP/transceiver value, not the maximum of the class.
- ONT min sensitivity (dBm)
- Weakest signal the ONT can still receive without errors. If received power falls below this, the link fails.
- ONT max input / overload (dBm)
- Strongest signal the ONT can tolerate. A short, lightly split link can exceed it and needs an attenuator.
- Fibre loss, downstream (dB/km)
- Attenuation of the fibre at the downstream wavelength (1490 nm for GPON). Loss = length in km x this value.
- Fibre loss, upstream (dB/km)
- Same, at the upstream wavelength (1310 nm for GPON). Used only for the upstream check.
- Connector loss (dB each)
- Loss at each mated connector pair. The model counts 2 + 2 per splitter stage.
- Splice loss (dB each)
- Loss per fusion splice. The model counts 2 per splitter stage plus 1 per km of cable.
- Design margin (dB)
- Safety allowance for ageing, repairs, temperature and measurement error. A path passes only if received power is at least this far above the sensitivity.
- Drop length (m)
- Cable from the last splitter to the customers. The last splitter is placed this far before each cluster.
- Max ONTs per PON port
- Most subscribers one PON port will serve (GPON allows up to 128 logically; many operators use 64). If the design exceeds it, you need more PON ports.
- ONT Tx power, upstream (dBm)
- Power the ONT transmits toward the OLT. Optional: needed with OLT Rx sensitivity for the upstream check.
- OLT Rx sensitivity (dBm)
- Weakest upstream signal the OLT can receive. Optional, with ONT Tx.
- Cable cost per fibre-metre
- Your price for one metre of one fibre. Optional. Together with splitter prices it gives a capital cost. Nothing is pre-filled.
- Design basis
- A sizes for today's customers only, B adds half the expected growth, C sizes for the full future count.
- Priority
- Changes the scoring weights: balanced, lowest initial cost, highest optical margin, or most spare capacity.
Results
- Path loss
- Total dB lost from the OLT to the ONT: fibre + splitters + connectors + splices.
- Rx power
- Power arriving at the ONT = launch power minus path loss.
- Margin
- Rx power minus sensitivity. It is the safety room left before the link fails.
- PASS / LOW MARGIN / BELOW SENSITIVITY / OVERLOAD / CANNOT VALIDATE
- PASS: margin at least the design margin. LOW MARGIN: positive but under the design margin. BELOW SENSITIVITY: link fails. OVERLOAD: signal too strong. CANNOT VALIDATE: receiver limits missing, so no pass is given.
- Two stage 1:a @s m + 1:b
- A first splitter (ratio 1:a) placed s metres from the OLT, feeding second splitters (1:b) placed near each customer cluster. Single stage means one splitter at the OLT.
- Fibre-m (fibre-metres)
- Sum of every fibre run in the design. It is a cost proxy: more fibre-metres means more cable.
- Splitters
- Total splitter count, a proxy for enclosures, joints and fault points.
- Spare / Output capacity
- Capacity is the total splitter ports installed. Spare is capacity minus the customers served.
- Stage-1 outputs insufficient
- Each second-stage splitter needs its own first-stage port. This error means more second-stage splitters are needed than the first splitter has outputs.
- Score
- Weighted blend of margin, fibre-metres, splitter count and spare ports among feasible candidates. Higher is better. Rejected candidates get no score.
- Ideal vs specified splitter loss
- Ideal = 10 x log10(N) dB. Specified is the real datasheet value, which is higher and is the one used.
- Unverified specs
- Number of splitter ratios still using generic default losses. Tick Verified in the library once you enter datasheet values.
Splitter library
Insertion loss values below are generic defaults, not a manufacturer specification. Edit them to your datasheet values and tick Verified. Prices are optional and never pre-filled.
Reference records (label-derived, not used by the optimizer)
| Record | Technology | Output | Coupling | Ideal loss | Label IL | Status |
|---|---|---|---|---|---|---|
| A: X-DB Technologies FBT 1×2 | FBT, 1310/1490/1550 nm, RL >55 dB | Blue | 80% | 0.97 dB | 1.13 dB (PDL 0.15) | Label-derived. Confirm port-to-loss mapping |
| Yellow | 20% | 6.99 dB | 6.90 dB (PDL 0.16) | Label-derived. Confirm port-to-loss mapping | ||
| B: AVNET triple-window SM 1×2 | Coupler, SMF-28e, connector N/A | Not established by the photographs | Specification required | Blocked from calculations | ||
Reports and export
This calculated design requires validation against actual equipment datasheets and field measurements before deployment.
Unit tests: